edit on



Chemical tests in support of the RoHS/WEEE Directive

for more information

Home > Services > Service
Tin Whisker testing to JESD201

Full Test requires enough samples to allow 96 inspection under optical microscopy and 18 under SEM for each condition used.

Preconditioning can be carried out if required – Cost to be advised, depending on which (if any) is required.



There are three conditions – Thermal cycling, temperature and humidity and High temperature and humidity.

Thermal cycling –
Class 1 & 2 products – 1500 cycles
4 inspections (0, 500, 1000 & 1500 cycles)
Reporting

Class 1a products - 1000 cycles
3 inspections (0, 500 & 1000 cycles)
Reporting

Temperature & Humidity –
Class 1 & 2 products – 4000 hours
5 inspections (0, 1k, 2k, 3k & 4k hours)
Reporting

Class 1a products - 1000 hours
2 inspections (0 & 1000 hours)
Reporting

High Temperature & Humidity –
Class 1 & 2 products – 4000 hours
5 inspections (0, 1k, 2k, 3k & 4k hours)
Reporting

Class 1a products - 1000 hours
2 inspections (0 & 1000 hours)
Reporting


Call us today to discuss your individual problems.
Contact:
Zoe Sullivan on +44-1727-871 307 or zoe.sullivan@itri.co.uk  