Full Test requires enough samples to allow 96 inspection under optical microscopy and 18 under SEM for each condition used.
Preconditioning can be carried out if required – Cost to be advised, depending on which (if any) is required.

There are three conditions – Thermal cycling, temperature and humidity and High temperature and humidity.
Thermal cycling – Class 1 & 2 products – 1500 cycles 4 inspections (0, 500, 1000 & 1500 cycles) Reporting
Class 1a products - 1000 cycles 3 inspections (0, 500 & 1000 cycles) Reporting
Temperature & Humidity – Class 1 & 2 products – 4000 hours 5 inspections (0, 1k, 2k, 3k & 4k hours) Reporting
Class 1a products - 1000 hours 2 inspections (0 & 1000 hours) Reporting
High Temperature & Humidity – Class 1 & 2 products – 4000 hours 5 inspections (0, 1k, 2k, 3k & 4k hours) Reporting
Class 1a products - 1000 hours 2 inspections (0 & 1000 hours) Reporting